ABC | Volume 114, Nº2, February 2020

Original Article Ribeiro et al. Simplified method to assess diastolic function by CMR Arq Bras Cardiol. 2020; 114(2):284-292 require additional sequences of images, such as phase‑contrast images, which mean longer CMR exam time. In two recent publications by Saba et al. 9 and Dusch et al., 7 CMR longitudinal LV shortening has been shown to be useful for diastolic dysfunction assessment. In the current study, we hypothesized that patients with severe aortic valve stenosis or regurgitation and preserved ejection fraction have diastolic LV dysfunction defined by motion of the atrioventricular junction (AVJ) at CMR. Methods Study population We retrospectively identified 26 patients with severe aortic valve disease (AVD) and normal ejection fraction, who underwent CMR and were scheduled for aortic valve replacement surgery, and 19 normal control subjects. Eleven of AVD patients (42.3%) had predominantly aortic insufficiency, and 15 of them (57.7%) had predominantly aortic stenosis. This sample size was based on the number of patients with confirmed diagnosis, available for analysis. The patients were clinically followed up at valve disease outpatient clinic of our institution. The exclusion criteria were: age under 18 and over 85 years old, diabetes mellitus, systemic arterial hypertension, dyslipidemia or concomitant significant coronary artery disease. All patients over 40 years old had a coronary angiography, and those with significant coronary artery disease (luminal stenosis >50%) were excluded. Patients with concomitant mitral valve disease were also excluded, as well as the ones with previous cardiac surgery and contraindications for CMR such as pacemaker use, metal clips or other ferromagnetic structures and claustrophobia. Healthy volunteers with no significant past medical history had been recruited to establish baseline AVJ motion values. In addition, 19 healthy volunteers (10 men), aged between 24 and 58 years old, without hypertension, diabetes mellitus, coronary artery disease or other significant past medical history, and all with normal CMR examinations were used for comparison with the 26 AVD patients. The CMR tests were performed with a 1.5 Tesla clinical scanner (Signa CV/i, GEMedical Systems, Waukesha, Wisconsin/ USA) and dedicated cardiac surface phased-array coil. After localization of the heart, eight to 12 contiguous short‑axis slices (8.0 mm slice thickness and 2mm gap between the slices), encompassing the entire LV and 4 long-axis slices were selected. The analysis was performed in a four-chamber view. Cine images were acquired with a steady-state free precession pulse sequence (SSFP) with temporal resolution of less than 50 ms and standard parameters: TR 3.9 ms, TE 1.8 ms, flip angle 45°, receiver bandwidth ± 125 kHz, field of view (FOV) of 34 x 34 cm, 256x160 matrix, voxel size 1.3 x 2.1 x 8.0mm. Image and data analyses The longitudinal motion of the AVJ was tracked through the cardiac cycle over 20 cardiac phases, on four-chamber view SSFP cine CMR images. The baseline position of the AVJ was defined at end diastole and its longitudinal displacement was measured relative to a reference line drawn between the LV apex (epicardial border, hypointense line corresponding to interface of myocardium and epicardial fat) and the inferior limit (hypointense line) of the coronary sinus running through the AV groove, immediately lateral to AVJ. These specific landmarks showed clear visualization on the cine-MR SSFP images and allowed for a robust tracking throughout the cardiac phases, with minimal blurring or loss of image definition. We did not use the midpoint of the mitral annulus 9 as we aimed to find the septal and lateral AVJ precisely; we also simplified the measure when we traced a unique line with well-defined landmarks. A simple straight line was traced between basal and apical landmarks using the Webpax software tool (Heart Imaging Technologies, LLC. Durham, NC, USA) (Figure 1). This line is a regular caliper available in all softwares capable of visualization of DICOM images. LV longitudinal lengths were divided by the longitudinal length at end diastole (maximum length) to provide a percent reduction of longitudinal length, corrected for individual heart sizes. Based on the plots of AVJ position versus time in the cardiac cycle (Figure 2), four motion variables were calculated: maximum longitudinal displacement (MD) of the AVJ, maximum velocity during early diastole (MVED), slope of the best-fit line of AVJ velocity in diastasis (VDS), and the ratio of VDS/MVED. The MVED values for each patient were calculated according to the time-versus-displacement graph, a linear regression (straight line) was adjusted for early diastole (slope). The same method was used for VDS considering now the diastasis time. All measurements were performed by two independent blinded radiologists. Cine-CMR images were used for the assessment of LV volume, mass, and function. Statistical analysis Continuous variables of the AVJ motion are presented as means and standard deviation. Normality distribution was assessed by Shapiro-Wilk test. Data obtained in AVD patients were compared to normal control subjects using the unpaired Student t-test. The categorical variables are presented in percentage. Bland-Altman plots were used to compare LV displacement parameters between patients and controls obtained by two independent blinded observers. The SAS System and SPSS statistical software packages were used for data analysis with a significance level of p < 0.05. Results Patients’ age ranged between 26 and 72 years old, with 19 men and seven women. The mean age of AVD patients and healthy volunteers in the study was 46.8 ± 13.7 and 43.1± 11.8 years, respectively. All patients were symptomatic, complaining of exertional dyspnea, angina, and syncope (Table 1). Indexes of LV volume and mass are shown in Table 2. All patients had normal or mild reduction of ejection fraction reduction (mean LV ejection fraction of 53.1 ± 9.9%). As expected, patients with predominant aortic regurgitation showed an eccentric hypertrophy pattern with end-diastolic volume and end-systolic volume significantly increased when compared with patients with predominant aortic stenosis, who presented a concentric hypertrophy pattern. 285

RkJQdWJsaXNoZXIy MjM4Mjg=